Attributes
| Order Code | MS6N-SV |
|---|
Description
Our soft start/quick exhaust valves MS6-SV cut off the power to critical components in the blink of an eye when an emergency stop is triggered. They also restart the system with the same care and reliability once the problem has been eliminated.
• With NPT connecting thread
• With safety functions
• For reducing pressure quickly and reliably and for building up pressure gradually
• Adjustable pressure build-up time
• Adjustable switch-through pressure
• Supply voltage 24 V DC
• Standard nominal flow rate <=6.500 l/min with grid dimension 62 mm
Specifications
| Series | MS |
|---|---|
| Size | 6 |
| Width dimension | 62 mm |
| Safety function | Exhausting, Prevention of unexpected start-up (pressurization) |
| Note on forced dynamization | Switching frequency at least once a month |
| Structural design | Piston gate valve, Piston seat |
| Actuation type | Electrical |
| Pilot air supply port | Internal |
| Sealing principle | Soft |
| Exhaust air function | Cannot be throttled |
| Manual override | None, At pilot control air solenoid valve: non-detenting, at soft start/quick exhaust valve: detenting, self-resetting, At pilot control air solenoid valve: non-detenting, detenting, at soft start/quick exhaust valve: detenting, self-resetting |
| Reset method | Mechanical spring |
| Type of control | Piloted |
| Valve function | 3/2-way, closed, monostable, Pressurization function |
| Operating pressure | 3, 10 bar |
| Pressure gauge | Set up for G1/4, Set up for G1/8, Red/green scale, With pressure sensor, with pressure sensor with LCD display, with pressure sensor with switching indicator, with pressure gauge |
| Normal nominal flow rate (normalized to DIN 1343) | 4300, 5700 l/min |
| Duty cycle | 100% |
| Signal status display | Floating contact, Switching outputs |
| Coil characteristics | 230 V AC: 50/60 Hz, initial power 3.0 VA, holding power 2.4 VA, 24 V DC: 1.5 W, 24 V DC: 1.8 W |
| Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] |
| Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
| Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
| Note on materials | RoHS compliant |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| Degree of protection | IP65, With plug socket |
| Temperature of medium | -10, 60 °C |
| Ambient temperature | -10, 60 °C |
| Storage temperature | -10, 60 °C |
| Shock resistance | Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27 |
| Vibration resistance | Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6 |
| Certification | RCM compliance mark, c UL us - recognized (OL) |
| KC characters | KC-EMV |
| CE marking (see declaration of conformity) | As per EU EMC directive, as per EU machinery directive, As per EU low voltage directive, As per EU RoHS directive |
| UKCA marking (see declaration of conformity) | To UK instructions for machines, To UK RoHS instructions |
| Certificate issuing authority | 01/205/5999.06/26 |
| For use in the food industry | See supplementary material information |
| Type of mounting | Alternatively:, In-line installation, With accessories |
| Mounting position | Any |
| Housing material | Die-cast aluminum |
| Seals material | NBR |
| Piston rod material | high-alloy stainless steel |
PDF Documents