Attributes
| Order Code | MS4(N)-DE |
|---|
Description
All functions for the preparation of compressed air: valves for pressure regulation, shut off, filter regulation, and soft start, with safety function; pressure and flow sensors, filter, dryer, water trap, sensors, lubricator, and distributor. In sizes 4, 6, 9, and 12.
• 2/2-way valve for slowly pressurizing pneumatic systems with electrically switchable pressure switchover point
• Supply voltage 24 V DC, 110, 230 V AC
• Switchable pressure switching point
• For advancing the actuators slowly and reliably into the initial position
• For avoiding sudden and unexpected movements
• Adjustable pressure build-up time
• Standard nominal flow rate <=1.800 l/min with grid dimension 40 mm
Specifications
| Actuation type | Electrical |
|---|---|
| Mounting position | Any |
| Manual override | Detenting, Non-detenting |
| Structural design | Piston seat |
| Reset method | Mechanical spring |
| Type of control | Piloted |
| Pilot air supply port | Internal |
| Flow direction | Non-reversible |
| Valve function | 2/2 |
| Pressure gauge | Set up for G1/4, Set up for G1/8, With pressure sensor, with pressure gauge |
| Switching position indication | with accessories |
| Operating pressure | 4, 14 bar |
| Normal nominal flow rate (normalized to DIN 1343) | 1000, 2000 l/min |
| Duty cycle | 100% |
| Certification | c UL us - recognized (OL) |
| KC characters | KC-EMV |
| CE marking (see declaration of conformity) | As per EU EMC directive, as per EU explosion protection directive (ATEX), As per EU low voltage directive, As per EU RoHS directive |
| UKCA marking (see declaration of conformity) | To UK RoHS instructions, To UK instructions for electrical equipment |
| Explosion protection certification outside the EU | EPL Dc (GB), EPL Gc (GB) |
| Explosion prevention and protection | Zone 2 (ATEX), Zone 2 (UKEX), Zone 22 (ATEX), Zone 22 (UKEX) |
| ATEX category gas | II 3G |
| ATEX category for dust | II 3D |
| Type of ignition protection for gas | Ex nA IIC T4 X Gc |
| Type of (ignition) protection for dust | Ex tc IIIC T105°C IP65 Dc X |
| Explosive ambient temperature | -10°C <= Ta <= +60°C |
| Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4], Inert gases |
| Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
| Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L |
| For use in the food industry | See supplementary material information |
| Temperature of medium | -10, 60 °C |
| Degree of protection | IP65 |
| Ambient temperature | -10, 60 °C |
| Product weight | 263 g |
| Signal status display | With accessories |
| Type of mounting | With accessories |
| Note on materials | RoHS compliant |
| Seals material | NBR |
| Housing material | Die-cast aluminum |
PDF Documents
Document
Open PDF